logo Class News No. 22/2014

17 June, 2014
 
Statutory Alert: Fuel change-over when entering and exiting emission control areas 
Applicability: All shipowners and operators
 

From 1 January, 2015, the maximum sulphur content of fuel oil used within the MARPOL Annex VI Emission Control Areas (ECAs) will be 0.10%, unless using an approved alternative means for controlling sulphur emissions. In most cases, the fuel used will be low-sulphur distillate oil (LSDO). Many ships operating both inside and outside ECAs will change-over between LSDO and residual fuel oil (RFO) when entering and exiting ECAs.

Lloyd’s Register Rule requirements
The Lloyd’s Register (LR) Rule requirements for fuel oil systems are contained within Pt.5 Ch.14 sections 2, 3 and 4; these contain design requirements for systems which are to operate on either LDSO or RFO grades, or both. LR also offers the optional descriptive note, DIST, for shipowners and operators applying industry best practice to the use of LSDO. The ShipRight Procedure for Assigning DIST Descriptive Note contains further guidance on measures to be considered by owners and operators.

In cases where existing fuel systems, engines or other equipment on LR classed ships are not suitable for operation on LSDO in addition to RFO, or where manufacturers have recommended equipment modifications, any proposed modifications must be submitted to LR for approval. If you are uncertain about whether equipment on board your ships requires approval, please contact your local LR office for advice.

Main points to consider when carrying out fuel change-over
Alternating satisfactorily between LSDO and RFO depends on owners and operators applying established change-over procedures and giving attention to maintenance and operating requirements. Some of the main points to consider are as follows:

Change-over procedures

  • Each ship should have an established and documented fuel change-over procedure which limits the maximum rate of temperature change when changing between RFO and LSDO.
  • Crews should receive training and instruction on applying the fuel change-over procedure.
  • Fuel oil spill returns from engines and other equipment should be routed and managed to avoid contamination of LSDO tanks with other fuels.
  • The compatibility of the RFO and LSDO should be checked. If instability occurs, it will generally be at the interface of the two fuels, necessitating more frequent filter change-over and cleaning to avoid blockage.

Maintenance

  • LSDO is less tolerant than RFO of worn fuel pumps; excessive barrel clearances will result in high leakage rates and failure to generate the required pressures, and may even prevent the engine starting. Excessive fuel supply and booster pump clearances will result in reduced delivery rates and pressures.
  • The cleaning and searching nature of LSDO relative to RFO, and the temperature differential between the two fuels, can result in seepage from pipe flanges, joints, seams and instrument connections.

Operation

  • Heating of LSDO will lower its viscosity below the minimal allowable limit of fuel equipment, requiring heating systems to be shut-down and meaning that indirect heating must be avoided. Cooling or even chilling of LSDO may be required. Fuel with a higher minimum viscosity (e.g., ISO 8217 DMZ) should be considered as an alternative.
  • The base number of the engine lubricants (particularly cylinder oil) must be suitable for the sulphur content of the fuel being used.
  • The sulphur content of LSDO is expected to be close to the limit; marginal contamination with higher sulphur fuels will cause it to be non-compliant. 


For further information

Speak to one of our experts at your local Lloyd's Register Group office. Or contact us via:

john.bradshaw@lr.org
+44 (0)20 7423 2502

Fleet management software survey

Please complete our quick survey about software that you're currently using to manage your fleet.

We will send you a specific report once we have collected all responses in July with benchmarks for the current industry standard and indications of future trends.

Take survey


Follow on Twitter | Like on Facebook| Follow on Linked In | Forward to a friend

Lloyd’s Register and variants of it are trading names of Lloyd’s Register Group Limited, its subsidiaries and affiliates. Copyright © Lloyd’s Register Group Limited. 2014. A member of the Lloyd’s Register group.

Lloyd’s Register Group Limited, its subsidiaries and affiliates and their respective officers, employees or agents are, individually and collectively, referred to in this clause as ‘Lloyd’s Register’. Lloyd’s Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd’s Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

Unsubscribe from this list | Update subscription preferences | Privacy policy