Statutory Alert: new SOLAS fire protection requirements for on-deck cargo areas of new ships designed to carry containers 
Applicability: All ships designed to carry containers on or above the weather deck, constructed on or after 1 January, 2016
 

The IMO has amended SOLAS regulation II-2/10, introducing new requirements for fire protection of on-deck cargo areas. The requirements apply to new ships constructed on or after 1 January, 2016, and include the following:   

  • All new ships designed to carry containers on or above the weather deck shall be fitted with at least one water mist lance, in addition to all other fire protection arrangements that should be provided on board as per existing regulations.
     
  • All new ships designed to carry five or more tiers of containers on or above the weather deck shall also be provided with mobile water monitors, in addition to the water mist lance mentioned above and all other fire protection arrangements that should be provided on board as per existing regulations. Ships with a breadth up to 30 m should be provided with at least two mobile water monitors and ships with a breadth exceeding 30 m or more should be provided with at least four mobile water monitors. 

The new requirements come in response to industry concerns regarding fire protection for cargo being carried on deck inside containers. These concerns included access to individual cargo units, as any container may be involved in a fire regardless of its location, and the equipment available to crews for tackling fires (currently only manual intervention using fire extinguishers and fire hoses is available, as weather decks are unlikely to provide any fixed fire suppression systems).

Guidance on design performance, testing and approval of mobile water monitors (MSC.1/Circ.1472)
The IMO has also released Circular MSC.1/Circ.1472 to provide guidance on design performance, testing and approval of mobile water monitors.

In addition, mobile water monitors will be included in future revisions of Circular MSC.1/Circ.1432 (Revised Guidelines for the Maintenance and Inspection of Fire Protection Systems and Appliances).

For further information

Speak to one of our experts at your local Lloyd's Register group office. Or contact us via:

fire.safety@lr.org


Follow on Twitter | Like on Facebook| Follow on Linked In | Forward to a friend

Lloyd’s Register and variants of it are trading names of Lloyd’s Register Group Limited, its subsidiaries and affiliates. Copyright © Lloyd’s Register Group Limited. 2015. A member of the Lloyd’s Register group.

Lloyd’s Register Group Limited, its subsidiaries and affiliates and their respective officers, employees or agents are, individually and collectively, referred to in this clause as ‘Lloyd’s Register’. Lloyd’s Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd’s Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

Unsubscribe from this list | Update subscription preferences | Privacy policy